NewApp Monitoring is liveSign up free
AgentbeamBeta
Open-source package vulnerability · NuGet

CVE-2024-24810: WiX Toolset's .be TEMP folder is vulnerable to DLL redirection attacks that allow the attacker to escalate privileges

highCVSS 3.1 8.2GHSA-7wh2-wxc7-9ph5

Summary .be TEMP folder is vulnerable to DLL redirection attacks that allow the attacker to escalate privileges. Details If the bundle is not run as admin, the user's TEMP folder is used and not the system TEMP folder. A utility is able to monitor the user's TEMP folder for changes and drop its own DLL into the .be/ .Local folder immediately when the .be folder is created.

Published Feb 8, 2024 · Updated Feb 9, 2024

Affected packages

wix

Ecosystem
NuGet
Affected
>= 4.0.0, < 4.0.4
Fixed in
4.0.4
Check
dotnet list package --include-transitive

wix

Ecosystem
NuGet
Affected
< 3.14.0
Fixed in
3.14.0
Check
dotnet list package --include-transitive

Advisory details

From the GitHub Advisory Database (CC BY 4.0).

Summary

.be TEMP folder is vulnerable to DLL redirection attacks that allow the attacker to escalate privileges.

Details

If the bundle is not run as admin, the user's TEMP folder is used and not the system TEMP folder. A utility is able to monitor the user's TEMP folder for changes and drop its own DLL into the .be/<bundle>.Local folder immediately when the .be folder is created. When the burn engine elevates, the malicious DLL receives elevated privileges.

PoC

As a standard, non-admin user:

  1. Monitor the user's TEMP folder for changes using ReadDirectoryChangesW
  2. On FILE_ACTION_ADDED, check if the folder name is .be
  3. Create a folder in .be named after the bundle + .Local (e.g. MyInstaller.exe.Local)
  4. Put the malicious COMCTL32.DLL in the .Local folder following the naming used for the real DLL (e.g. MyInstaller.exe.Local/x86_microsoft.windows.common-controls_.../COMCTL32.dll)
  5. Do hacker things when the engine escalates and the malicious DLL is loaded

Proper naming for the path can be obtained by using GetModuleHandle("comctl32.dll") and GetModuleFileName.

Impact

DLL redirection utilizing .exe.Local Windows capability. This impacts any installer built with the WiX installer framework.

Credited to ppv-milestone, robmen.

References

How this page is made: the data panel comes from the GitHub Advisory Database, CISA’s KEV catalog, the NVD and FIRST EPSS, and updates twice a day. No analysis has been written for this entry yet. Methodology

More NuGet vulnerabilities

All NuGet entries