CVE-2025-59824: Omni Wireguard SideroLink potential escape
Overview Omni and each Talos machine establish a peer-to-peer (P2P) SideroLink connection using WireGuard to mutually authenticate and authorize access. In this setup, Omni assigns a random IPv6 address to each Talos machine from a /64 network block. Omni itself uses the fixed ::1 address within that same block.
Published Sep 24, 2025 · Updated Oct 23, 2025
Affected packages
github.com/siderolabs/omni
- Ecosystem
- Go
- Affected
- < 0.48.0
- Fixed in
- 0.48.0
- Check
go list -m github.com/siderolabs/omni
Advisory details
From the GitHub Advisory Database (CC BY 4.0).
Overview
Omni and each Talos machine establish a peer-to-peer (P2P) SideroLink connection using WireGuard to mutually authenticate and authorize access.
In this setup, Omni assigns a random IPv6 address to each Talos machine from a /64 network block. Omni itself uses the fixed ::1 address within that same block.
From Omni's perspective, this is a WireGuard interface with multiple peers, where each peer corresponds to a Talos machine. The WireGuard interface on Omni is configured to ensure that the source IP address of an incoming packet matches the IPv6 address assigned to the Talos peer. However, it performs no validation on the packet's destination address.
The Talos end of the SideroLink connection cannot be considered a trusted environment. Workloads running on Kubernetes, especially those configured with host networking, could gain direct access to this link. Therefore, a malicious workload could theoretically send arbitrary packets over the SideroLink interface.
---
Impact
This vulnerability creates two distinct attack scenarios based on Omni's IP forwarding configuration.
- IP Forwarding Disabled (Default) If
IP forwardingis disabled, an attacker on a Talos machine can send packets over SideroLink to any listening service on Omni itself (e.g., an internal API). If Omni is running in host networking mode, any service on the host machine could also be targeted. While this is the default configuration, Omni does not enforce it.
- IP Forwarding Enabled If
IP forwardingis enabled, an attacker on a Talos machine can communicate with other machines connected to Omni or route packets deeper into Omni's network. Although this is not the default configuration, Omni does not check for or prevent this state.
Patches
The problem has been fixed in Omni >= 0.48.0, the commit is https://github.com/siderolabs/omni/commit/a5efd816a239e6c9e5ea7c0d43c02c04504d7b60
Workarounds
Disable IP forwarding, implement strict firewall rules.
References
None
Credited to smira, Unix4ever.
References
How this page is made: the data panel comes from the GitHub Advisory Database, CISA’s KEV catalog, the NVD and FIRST EPSS, and updates twice a day. No analysis has been written for this entry yet. Methodology
More Go vulnerabilities
All Go entriesCVE-2026-45720
Omni has a TOCTOU race condition that allows multiple concurrent uses of a single-use SAML session token
high7.0Jun 5, 2026CVE-2026-45723
Omni: Operator can traverse image-factory API paths via unsanitized `talos_version` in CreateSchematic
low2.7Jun 5, 2026CVE-2026-45726
Omni: Reader-level users can retrieve imported cluster CA keys via ResourceService
high7.6Jun 5, 2026CVE-2025-59836
Omni is Vulnerable to DoS via Empty Create/Update Resource Requests
medium5.3Oct 13, 2025CVE-2025-61688
Omni vulnerable to information leak via API
high8.6Oct 13, 2025